Class 1

Class 1 is for systems within a single building having only one telecommunications room (TR) that all workstation cabling runs to. The TR, horizontal links (HL’s) and telecommunications main grounding busbar (TMGB) are required to be labeled and administered. If the system owner wishes to document pathways or firestopping locations, Class 2 administration should be used. Class 1 systems require the identifiers and records for the following:

  • TS Identifier
  • Horizontal LInks
  • Telecommunications Main Grounding Busbar (TMGB)
  • Telecommunications Grounding Busbar (TGB)

Class 2

Class 2 is for systems within a single building that are served by multiple TR’s. Class 2 includes administration for backbone cabling, multi-element grounding & bonding, firestopping as well as all the items within Class 1. Class 2 systems require the identifiers and records for the following:

  • All Class 1 Elements
  • Intra-Building Backbone Cable
  • Intra-Building Backbone Pair or Strand
  • Firestopping

Class 3

Class 3 is for systems spanning multiple buildings, known as a campus environment. Class 3 includes administration for buildings and inter-building cabling as well as all elements of Class 2. Administration of pathways, spaces and outside plant elements is recommended. Class 3 systems require the identifiers and records for the following:

  • All Class 2 Elements
  • Inter-Building Backbone Cable
  • Inter-Building Backbone Pair or Strand
  • Building

Class 4

Class 4 is for systems spanning multiple campuses, known as a multi-site system. Class 4 includes administration for each site as well as all elements of Class 3. Administration of pathways, spaces and wide area network connections is recommended. Class 4 systems require the identifiers and records for the following:

  • All Class 3 Elements
  • Site or Camput

Educate

Effects of EMI on a Network
Firestopping

Labeling

Structured Cabling System

Broadband Network Upgrade Services

Boradband Network Sweep & Certification

Node Splits & Segmentation Services

Bandwith Enhancement Services

Bi-Annual FCC Proof of Performance Services

Fiber Optic Splicing

 

Quick Reference Guide to 606A Labeling


What People Are Saying

“I decided to work with Tero because they are experienced individuals that get the job done right and in a timely manner. What stands out most to me is the knowledge level of the technicians doing the work. They are not laborers pulling cable. They are quality technicians that know how to do their job and they do it well. I expect top quality work and I get it with Tero. I have learned that I no longer have to keep up with cabling standards and best practices. I can rely on Tero technicians to do that for me. I have always appreciated the way Tero has gone above and beyond to make sure we were happy customers. On more than one occasion, I have had a job that required emergency attention and Tero was willing and able to provide an immediate solution. Tero has been an asset that I know I can count on to do a job. When I need a cabling solution, Tero is the only call I need to make. Over the past several years, I have used Tero on quite a few projects. While working with them I have come to know the technicians pretty well. I have noticed that most of the same technicians are still working for the company. I think that says a lot about Tero as a company. In an industry with a high turnover rate, their employees remain loyal to the company and their job. That is hard to come by these days.”